Acrartex Float-Free 406 Memory Capsule Manual de usuario Pagina 31

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 35
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 30
27 Y1-03-0202 Rev. E
12.2. Status Request for Error Flag Word Example
Send Status Request
command
to RLB-35MC
Start
Command echoed
back?
Read data packet from
RLB-35MC
Flag Word = 0?
Close socket
connection
End
Yes
No
No
Yes
Open socket
Connection on Port
7200
Read Error Flag Word only.
AC,53,CA,35,53,00,00,00,00,00,00,00,00,00,00,00
Status request is on port 7200
RLB-35MC Fail
Note that the ‘Status’ button of the demo software demonstrates this
command. The error flags are returned in response to this command.