28 Y1-03-0202 Rev. E
12.3. Test Request for Error Flags, CFC Size, and Software Version Example
Send Test Request
command
to RLB-35MC
Start
Command echoed
back?
Read data packet from
RLB-35MC
Flag Word = 0?
Close socket
connection
End
Yes
No
No
Yes
Open socket
Connection on Port
7200
Read Error Flag Word, CFC Size, and Software Version.
AC,53,CA,35,45,30,00,00,00,00,00,00,00,00,00,00
Test request is on port 7200
RLB-35MC Fail
Note that the ‘Test’ button of the demo software demonstrates this
command. The error flags, CFC size, and software version are returned in
response to this command.